The brake pressure sensor does not require calibration often.Calibration of the brake pressure sensor might be required aftercertain service procedures are performed. Some of these proceduresare as follows:
Electronic brake control module (EBCM) replacementBrake pressure modulator valve assembly replacementThe Brake Pressure Sensor Calibration procedure can becompleted with a scan tool using the following steps:
Apply the parking brake, or set the transmission in the Pposition.Release the brake pedal.Install the scan tool to the data link connector.Ignition ON, engine OFFSelect Brake Pressure Sensor Calibration in the EBCMConfiguration/Reset Functions list.Follow the scan tool directions to complete the calibrationprocedure.Clear any DTCs that may be set.Work Stall Test Warning
Warning:One or more of the following guidelines may apply whenperforming specific required tests in the work stall:When a test requires spinning the drive wheels with thevehicle jacked up, adhere to the following precautions:Do not exceed 56-km/h (35-mph) whenspinning one drive wheel with the other ...