Caution:After cleaning the transmission components, allow to air dry.Do not use cloth or paper towels in order to dry any transmissioncomponents. Lint from the towels can cause componentfailure. Caution:Do not reuse cleaning solvents. Previously used solvents maydeposit sediment which may damage the component. Preliminary ProceduresThoroughly clean the housing with clean solvent.Inspect the piston bores and retainer ring grooves for wear,damage or porosity. | |
1 | 1–2–3–4 Clutch Spring RetainerGroove |
2 | 1–2–3–4 Clutch PistonBore |
3 | Low and Reverse Clutch Spring Retainer Groove |
4 | Low and Reverse Clutch Piston Bore |
5 | Clutch Oil Passages |
6 | Air Bleed Passages |
Torque Converter Housing with Fluid Pump Assembly Removal (Non Hybrid) Automatic Transmission Unit Transmission Oil Pump
Torque Converter Housing with Fluid Pump Assembly RemovalCalloutComponent Name1Torque Converter and Differential Housing Bolts-M8-x-30-(Qty:-15)2Torque Converter with Fluid Pump Housing Assembly3Torque Converter Housing GasketNote:Discard the seal. It is not reusable.4Fluid Pump Seal AssemblyNote:Di ...